Repository logo
 

Adherencia de varillas impresas en 3D de filamento de fibra de carbono al concreto de baja resistencia

dc.campusUNITEC TGUes_ES
dc.catalogadorAlexander Romeroes_ES
dc.collectionTrabajo de Investigaciónes_ES
dc.contributor.advisorVíctor Alonzo Martínez Reyeses_ES
dc.contributor.advisorEduardo Favell Núñez Rodríguezes_ES
dc.contributor.advisorKarla Antonia Uclés Brevées_ES
dc.contributor.authorMarcos David Rivera Lozanoes_ES
dc.contributor.authorLeonardo López Morenoes_ES
dc.coverageTegucigalpa, Francisco Morazán, Hondurases_ES
dc.date.accessioned2024-05-21T22:10:00Z
dc.date.available2024-05-21T22:10:00Z
dc.date.issued2024-03-25
dc.date.terna2024-01-01
dc.ddc624.177 R621es_ES
dc.description.abstractEl proyecto de investigación se ha realizado con el propósito de profundizar la investigación de alternativas para el refuerzo de elementos estructurales como las vigas y las columnas, por lo que como objetivo principal se ha definido hacer uso de la impresión 3D como herramienta para fabricar el prototipo del refuerzo con fibra de carbono, para lo que se han realizado 4 diseños diferentes, de varilla lisa; con corrugas a lo largo de toda la extensión; con la mitad de la cantidad de corrugas, y con un cuarto de corrugas. Luego de concluir el diseño con el programa de SolidWorks, las varillas han sido impresas con ayuda del FABLAB de UNITEC. Al concluir la impresión, se han preparado 4 núcleos de concreto de forma cilíndrica que sirvieran para ensayar las varillas en una prueba de grado de adherencia. Para realizar el ensayo, se han utilizado las normas ASTM C234-91 “método de prueba estándar para comparar concreto para la adherencia desarrollada con el acero de refuerzo” y IS: 2770 (Part I) – 1967 (Reaffirmed 2007) “método de prueba estándar en concreto reforzado: ensayo de extracción”. Luego de ensayar varillas lisas y con 0.64, 0.32, y 0.18 corrugas/cm, se ha descubierto que la carga máxima aplicable es de 3, 27, 44 y 80 kg respectivamente, donde todas las varillas fueron extraídas de sus núcleos de concreto exceptuando la varilla con 0.64 corrugas/cm, para esta se recomienda repetir el procedimiento conforme a las indicaciones en el Capítulo VII: Recomendaciones. Con estos datos se ha podido verificar adherencia del filamento de fibra de carbono al concreto para corrugas distribuidas como mínimo en 0.64 corrugas/cm. Las varillas extraídas han presentado una perdida en su integridad estructural en las partes que entraron en contacto directo con el concreto durante el proceso de fraguado.es_ES
dc.description.abstractenglishThe research project has been carried out with the purpose of deepening the investigation of alternatives for the reinforcement of structural elements such as beams and columns, so the main objective has been defined to use 3D printing as a tool to manufacture the prototype. of the carbon fiber reinforcement, for which 4 different designs have been made, with smooth rods; with deformations along the entire length; with half the number of deformations, and with a quarter of deformations. After concluding the design with the SolidWorks program, the rods have been printed with the help of UNITEC's FABLAB. At the end of the printing, 4 cylindrical concrete cores were prepared to test the rods in an adhesion “Pull-out” test. To carry out the test, ASTM C234-91 “Standard test method for comparing concrete for bond developed with reinforcing steel” and IS: 2770 (Part I) – 1967 (Reaffirmed 2007) “Standard in reinforced concrete: Pull-out test.” After testing smooth rods with 0.64, 0.32, and 0.18 deformations/cm, it has been discovered that the maximum applicable load is 3, 27, 44 and 80 kg respectively, where all the rods were extracted from their concrete cores except the rod with 0.64 deformations/cm, for this rod it is recommended to repeat the procedure according to the indications in Chapter VII: Recommendations. With this data, it has been possible to verify adhesion of the carbon fiber filament to the concrete for rods distributed with at least 0.64 deformations/cm. The extracted rods have shown a loss in their structural integrity in the section that came into direct contact with the concrete during the setting process.es_ES
dc.disciplineIngeniería y TI/ Engineering and ITes_ES
dc.facultyFacultad de Ingenieríaes_ES
dc.formatPDFes_ES
dc.identifier.urihttps://repositorio.unitec.edu/xmlui/handle/123456789/13148
dc.languageEspañoles_ES
dc.publisherUniversidad Tecnológica Centroamericana UNITECes_ES
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceUniversidad Tecnológica Centroamericana UNITECes_ES
dc.subjectAdherenciaes_ES
dc.subjectConcreto reforzadoes_ES
dc.subjectCorrugases_ES
dc.subjectFilamento de fibra de carbonoes_ES
dc.subjectImpresión 3Des_ES
dc.thesis.degreelevelPregradoes_ES
dc.thesis.degreenameIngeniería Civil / I-03es_ES
dc.titleAdherencia de varillas impresas en 3D de filamento de fibra de carbono al concreto de baja resistenciaes_ES
dc.typeThesises_ES

Files

Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Adherencia de varillas impresas en 3D de filamento de fibra de carbono al concreto de baja resistencia.pdf
Size:
1.78 MB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
20180807 Autorización para uso del CRAI_Marcos_Leonardo.pdf
Size:
131.23 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: