“EL USO DE CENIZA VOLANTE COMO SUSTITUCIÓN DEL CEMENTO PORTLAND ESTRUCTURAL ADVANCED EN EL CONCRETO HIDRÁULICO EN SAN PEDRO SULA, HONDURAS 2023”
dc.campus | UNITEC SPS | es_ES |
dc.codigocarrera | I-03 | es_ES |
dc.collection | -- | es_ES |
dc.contributor.advisor | Hector Wilfredo Padilla | es_ES |
dc.contributor.author | Jurgen Estuardo Martínez Carrillos; Krizia Isabella Bustillo Portillo | es_ES |
dc.coverage | San Pedro Sula, Cortés, Honduras | es_ES |
dc.date.accessioned | 2023-11-01T17:39:19Z | |
dc.date.available | 2023-11-01T17:39:19Z | |
dc.date.issued | 31/08/2023 | |
dc.date.terna | 2023-04-01 | |
dc.description.abstract | La finalidad del trabajo de investigación presente es evaluar la ceniza volante en el concreto hidráulico y corroborar si la implementación de esta influye de manera positiva las resistencias a compresión y flexión utilizando agregados de Eterna S.A. en la ciudad de San Pedro Sula, Honduras. El propósito es analizar el comportamiento físico y mecánico del concreto hidráulico haciendo sustitución porcentual del cemento Portland estructural advanced por ceniza volante e identificar el beneficio que aporta a la fabricación del concreto hidráulico. A los agregados utilizados en la investigación se les realizó los respectivos ensayos indicados por las normas ASTM para conocer las propiedades de estos, por otro lado, la dosificación con la ceniza volante que se ha usado fue en base a los porcentajes propuestos, siendo de 10%, 15%, 20%, 25% y 30%. Los resultados a los 28 días a compresión son de 5360 psi sin reemplazo, 3760 psi para un 10% de sustitución, 4770 psi con un 15% de sustitución, 3810 psi con un 20% de sustitución, 3820 psi con el 25% de sustitución y 2470 psi con el 30% de sustitución. Los resultados a los 28 días a flexión han resultado de 660 psi sin reemplazo, 630 psi con el 10% de sustitución, 660 psi con el 15% de sustitución, 660 psi con el 20%, 650 psi con el 25% y 490 psi con el 30% de sustitución. En conclusión, resulta funcional y beneficioso hacer sustituciones a partir del 10% hasta 25% de sustitución del cemento Portland estructural advanced tipo I por la ceniza volante. | es_ES |
dc.description.abstractenglish | The purpose of the present research is to evaluate fly ash in hydraulic concrete and to corroborate if its implementation positively influences compressive and flexural strengths using aggregates from Eterna S.A. in the city of San Pedro Sula, Honduras. The purpose of this investigation is to analyze the physical and mechanical behavior of hydraulic concrete with the percentage substitution of Portland cement structural advanced for fly ash and to identify the benefit it brings to the manufacture of hydraulic concrete. The aggregates used in the research were subjected to the respective tests indicated by the ASTM norms to know their properties; on the other hand, the dosage with the fly ash used was based on the proposed percentages of 10%, 15%, 20%, 25% and 30%. The results at 28 days in compression are 5360 psi without replacement, 3760 psi for 10% replacement, 4770 psi with 15% replacement, 3810 psi with 20% replacement, 3820 psi with 25% replacement and 2470 psi with 30% replacement. The 28-day flexural results were 660 psi without replacement, 630 psi with 10% replacement, 660 psi with 15% replacement, 660 psi with 20% replacement, 650 psi with 25% replacement and 490 psi with 30% replacement. In conclusion, it is functional and beneficial to make substitutions from 10% to 25% replacement of Portland cement structural advanced for fly ash. | es_ES |
dc.discipline | Administración y Negocios / Business and Management | es_ES |
dc.faculty | Facultad de Ingeniería | es_ES |
dc.identifier.uri | https://repositorio.unitec.edu/xmlui/handle/123456789/12769 | |
dc.language | Español | es_ES |
dc.language.iso | es-HN | es_ES |
dc.publisher | Universidad Centroamericana UNITEC | es_ES |
dc.rights | Attribution-NonCommercial-ShareAlike 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.source | Universidad Tecnológica Centroamericana UNITEC | es_ES |
dc.subject | Ceniza Volante (CV), Cemento, Concreto Hidráulico, Resistencia a la compresión, Resistencia a la flexión. | es_ES |
dc.thesis.degreelevel | Pregrado | es_ES |
dc.thesis.degreename | Ingeniería Civil | es_ES |
dc.title | “EL USO DE CENIZA VOLANTE COMO SUSTITUCIÓN DEL CEMENTO PORTLAND ESTRUCTURAL ADVANCED EN EL CONCRETO HIDRÁULICO EN SAN PEDRO SULA, HONDURAS 2023” | es_ES |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- El uso de ceniza volante como sustitución del Cemento Portland Estructural Advanced en el concreto hidráulico en San Pedro Sula, Honduras 2023.pdf
- Size:
- 8.63 MB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: