Mostrar el registro sencillo del ítem

dc.contributor.advisorING. ADA RODRIGUEZes_ES
dc.contributor.advisorING. OTTO FLORESes_ES
dc.contributor.advisorING. SERGIO PAREDESes_ES
dc.contributor.authorANGEL JOSÉ CACERES ULLOAes_ES
dc.contributor.authorDANIEL ENEA MALTAes_ES
dc.date.accessioned2024-07-09T23:12:17Z
dc.date.available2024-07-09T23:12:17Z
dc.date.issued2024-04-24
dc.identifier.urihttps://repositorio.unitec.edu/xmlui/handle/123456789/13200
dc.description.abstractLa comunidad de Barrio Canahuati localizada en el municipio de Choloma esta experimenta escasez de agua potable debido a fallos en la línea de conducción y a la capacidad limitada de su tanque de almacenamiento, sumando a esto la red de distribución que ellos poseen ya sobrepaso su periodo de diseño por lo tanto no cumplirá para satisfacer la dotación mínima que la población necesita. Para esto es necesario diseñar geométrica y estructuralmente un modelo de red de distribución de agua potable, que permita mejorar la calidad de vida de los habitantes de la zona. Se propone una iniciativa para solventar esta problemática, mediante un levantamiento topográfico de la zona donde se verifica las zonas más altas de la comunidad, así como las más bajas las cuales son 70.54 msnm la zona más alta, 21.73 msnm la zona más baja y 140.86 msnm la zona donde se ubica el tanque que distribuye a toda la comunidad. Se hizo una simulación mediante el programa EPANET el cual nos indicó que el sitio tiene presiones elevados en los lados bajos que no cumplen con la normativa del SANAA. Otro problema encontrado fue que el tanque que hay en la comunidad no cumple con las dotaciones que se requieren dejando a los habitantes sin agua durante días. Todo lo anterior, con el fin de analizar la recolección de datos para realizar el diseño de la red de distribución de agua potable el cual tiene una longitud de 1.7 km y está comprendido por tubería de 2”. Para esta solución se propuso un diseño que en sus primeros tramos de red se cambie el diámetro de tubería a 3” con el fin de reducir considerablemente las presiones en las partes bajas de la comunidad, así como también proponer un tanque con un volumen de 25,000 galones que iría a la par del que ya está existente. Añadiendo también un tanque elevado de 25,000 galones esto para tener un tanque auxiliar al momento que la línea de conducción este dañada. Con esto se logrará solventar el problema de la escasez de agua en la comunidad.es_ES
dc.formatPDFes_ES
dc.languageEspañoles_ES
dc.publisherUniversidad Tecnológica Centroamericana UNITECes_ES
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceUniversidad Tecnológica Centroamericana UNITECes_ES
dc.subjectTanquees_ES
dc.subjectAguaes_ES
dc.subjectRed de distribuciones_ES
dc.title"DISEÑO DE RED DE DISTRIBUCIÓN AGUA POTABLE EN EL BARRIO CANAHUATI DE LA ALDEA BIJAO, CHOLOMA"es_ES
dc.typeThesises_ES
dc.description.abstractenglishThe community of Barrio Canahuati located in the municipality of Choloma is experiencing a shortage of drinking water due to failures in the pipeline and the limited capacity of its storage tank, adding to this the distribution network that they have already exceeded its design period and therefore will not meet the minimum supply that the population needs. For this reason, it is necessary to design geometrically and structurally a model of drinking water distribution network, which will improve the quality of life of the inhabitants of the area. An initiative is proposed to solve this problem, by means of a topographic survey of the zone where the highest zones of the community are verified, as well as the lowest ones which are 70.54 masl the highest zone, 21.73 masl the lowest zone and 140.86 masl the zone where the tank that distributes to the whole community is located. A simulation was made using the EPANET program, which indicated that the site has high pressures on the low sides that do not comply with SANAA regulations. Another problem encountered was that the existing tank in the community does not meet the required supplies, leaving the inhabitants without water for days. All the above, to analyze the data collection for the design of the drinking water distribution network, which has a length of 1.7 km and is comprised of 2" pipe. For this solution, a design was proposed for the first sections of the network to change the pipe diameter to 3" to reduce the pressures in the lower parts of the community, as well as to propose a tank with a volume of 25,000 gallons that would be on a par with the existing one. Also adding an elevated tank of 25,000 gallons to have an auxiliary tank when the pipeline is damaged. This will solve the water shortage problem in the community.es_ES
dc.coverageSan Pedro Sula, Cortes,Hondurases_ES
dc.catalogadorMariam Pazes_ES
dc.facultyFacultad de Ingenieríaes_ES
dc.thesis.degreenameIngeniería Civil / I-03es_ES
dc.thesis.degreelevelPregradoes_ES
dc.disciplineIngeniería y TI/ Engineering and ITes_ES
dc.ddc628 C118es_ES
dc.campusUNITEC SPSes_ES
dc.collectionPráctica Profesionales_ES
dc.date.terna2024-04-24


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-ShareAlike 3.0 United States